Cartridge labels · Micron chart

Water Filter Micron Chart: 1, 5 and 20 Microns

The number describes a particle rating. It does not, on its own, establish cartridge fit, pressure loss or a treatment claim.

What does a water filter's micron rating mean?

A micron (µm) is one thousandth of a millimeter. A smaller stated number describes a finer particle rating, but compare the rating type, efficiency and test conditions as well as the number. A nominal 5-micron label is not the same specification as an absolute 5-micron label.

This guide helps you read a cartridge label. It does not prescribe a micron number for a well, infer contaminant removal from pore size alone, or replace an exact-system performance or certification record.

1, 5 and 20 micron water filter chart

These are real manufacturer label examples, checked October 24, 2026. Pentair's P-series and S1-series specification tables explicitly identify the ratings below as nominal. They are examples for reading specifications, not interchangeable replacements or recommendations for your system.

Scroll the chart sideways if a column is outside the screen. With a keyboard, focus the chart area and use Left/Right.

RatingExact manufacturer exampleRating typeWhat to check next
1 micronPentair Pentek P1, part 155225-43NominalRequired efficiency/test conditions, approved housing and actual operating flow.
5 micronsPentair Pentek P5, part 155014-43NominalThe same number on a different cartridge does not establish the same performance or fit.
20 micronsPentair Pentek S1, part 155001-43NominalMaterial, dimensions, supply restrictions and the exact manufacturer's instructions.

Nominal versus absolute: ask what was measured

CDC distinguishes nominal or mean pore size from absolute pore size. Its nominal example can include pores above and below the named size; its absolute example sets a maximum pore size. Read the exact manufacturer's definition and test conditions rather than silently converting one description into the other.

The number alone does not supply a universal removal percentage. Ask which efficiency or particle-retention test supports the rating and whether the document describes the cartridge, a component or the complete system.

Two label-reading traps

A model suffix can describe length, not microns

Pentair's P-series table lists P5-20 as a 5-micron nominal cartridge with a 20-inch length. It is not a 20-micron cartridge. Read the separate rating and dimension columns; a product title can contain both numbers.

A 5-micron title can leave the rating type unstated

iSpring's FP25B product page describes a 20 × 4.5-inch, 5-micron sediment cartridge. The description checked for this guide does not identify that rating as nominal or absolute. Keep that distinction unknown unless the manufacturer supplies it; do not add a label from a different brand's datasheet.

Will a smaller micron rating reduce water pressure?

Micron rating alone cannot predict pressure loss. Media, cartridge area, flow and accumulated loading also matter. Use the exact manufacturer's pressure-drop information under its stated conditions, including the housing and other treatment equipment.

Pentair's P-series sheet includes cartridge pressure/flow data. Those figures are not a measurement of the pressure delivered by a complete installation. Do not compare data taken at different flows, or transfer one cartridge's pressure result to another product.

Can I replace a 20-micron cartridge with a 5-micron one?

A smaller number alone is not approval to substitute. Confirm the exact system's permitted cartridge, dimensions, end configuration, material, treatment stage and operating requirements. Ask the manufacturer for clarification when the rating type or pressure data are missing.

  1. Record the system model, current cartridge part and stage position.
  2. Read the replacement's rating type, dimensions and performance conditions.
  3. Confirm written compatibility and the pressure/flow implications with the manufacturer or installer.
  4. Budget the approved replacement and use the exact service instructions.

Sources

Editorial transparency

This page is governed by our editorial policy, review methodology, and corrections process.