What size whole-house water filter do I need?
Start with peak simultaneous demand and the manufacturer's dynamic-pressure and pressure-drop data. Then match water chemistry, pipe and port size, and service clearance. If flow or pressure is unknown, measure it or obtain professional sizing rather than relying on bedroom count or a headline GPM figure.
| Sizing input | Record before choosing |
|---|---|
| Peak simultaneous demand | Measure or calculate the home's peak use. |
| Dynamic pressure | Record pressure at the installation point while demand is running. |
| Pressure-drop data | Use the manufacturer's curve at the required flow. |
| Water chemistry | Match media to measured conditions and feed-water limits. |
| Pipe and port size | Confirm line and connection compatibility. |
| Service clearance | Allow space for cartridge changes, media service, and bypass access. |
Copy this sizing worksheet before asking for a quote
Copy or print these fields into your planning notes. Use actual fixture labels, measurements and exact-model documents. Leave missing information unknown; this sheet does not select equipment or approve an installation.
If the table extends beyond the screen, scroll it sideways. With a keyboard, focus the table area and use Left/Right.
| Input | Your planning record | Evidence to attach |
|---|---|---|
| Simultaneous use | Which outlets can run together? Record each flow in GPM and the scenario total. | Actual fixture labels and measured flow where needed; include appliances and outdoor use. |
| Static pressure | Pressure at the proposed installation point with no demand running: ____ psi. | Dated gauge reading and measurement location. |
| Dynamic pressure | Pressure there during the same simultaneous-use scenario: ____ psi. | Dated reading plus which outlets were running. |
| Equipment losses | Exact system, cartridge, condition and pressure-drop data at the needed flow: ____. | Manufacturer curve and its test conditions; include the complete treatment train. |
| Remaining requirements | Required downstream pressure and acceptable losses: ____. | Fixture/equipment requirements and an installer's assessment. |
| Water test and feed-water limits | Measured condition, lab result and units: ____. Exact model’s documented feed-water limit: ____. | Dated lab report and exact-model manufacturer documentation. Leave unknowns blank. |
| Fit and servicing | Pipe/port sizes, model-approved cartridge size, bypass and service clearance: ____. | Exact installation manual and site measurements. |
Worked flow example: 2 + 2 + 1.5 = 5.5 GPM
Hypothetical arithmetic only: suppose two showerheads each labeled 2.0 GPM and one bathroom faucet labeled 1.5 GPM run together. The sum of those example label values is 5.5 GPM. EPA WaterSense's showerhead and bathroom-faucet pages support these example maximum label values; they are not measurements of your home.
Actual simultaneous flow depends on the fixtures, pressure, supply and other demand. Include the outlets that matter in your household rather than assuming this three-outlet scenario is a complete peak-demand calculation.
| Example input | Arithmetic | What remains unknown |
|---|---|---|
| Two showerheads | 2 × 2.0 = 4.0 GPM | Your exact fixture ratings and actual flow under demand. |
| One bathroom faucet | 1 × 1.5 = 1.5 GPM | Its rating conditions and the rest of the household demand. |
| Scenario label-value total | 4.0 + 1.5 = 5.5 GPM | Dynamic pressure, full-system pressure loss and acceptable downstream pressure. |
Five inputs decide size
- Peak simultaneous demand in gallons per minute.
- Static and dynamic pressure at the installation point.
- Water chemistry, sediment load, and the media's feed-water limits.
- Pipe and port size plus the manufacturer's pressure-drop data.
- Wall width, depth, vertical service clearance, drainage during filter changes, power, and bypass access.
Rated flow is not household flow
A headline ‘15 GPM’ may be a maximum operating value rather than a certified service flow at a stated pressure drop. Ask for the pressure-drop curve, define the household's simultaneous demand, and include other equipment in the train. A one-inch port does not guarantee one-inch-system performance.
Design for the filter change
- Measure the assembled width, depth, and height.
- Add the manual's required clearance below housings or above media tanks.
- Provide isolation and a code-compliant bypass where appropriate.
- Plan where water and the weight of a wet cartridge go during service.
- Protect equipment from freezing, heat, sunlight, contamination, and unsupported pipe loads.
When professional sizing matters most
- Private-well pumps and pressure tanks.
- Iron, manganese, sulfur, or microbial treatment.
- Multiple devices in series.
- Low pressure, high peak demand, or large homes.
- Drain, electrical, grounding, backflow, permit, or local-code questions.